INTRODUCTION
For the insulation of solid ground floor constructions we recommend
the use of KingspanKooltherm® K3 Floorboard (premium
performance CFC/HCFC–free rigid phenolic insulation) positioned below
the floor slab or beneath a floor screed. It can be used over whole
floor areas or as an edge insulant at the floor perimeter. Ideal for
both newbuild and refurbishment.
Figure 1 Below the floor slab
ACHIEVING U–VALUES
The table below details typical thickness of KingspanKooltherm®
K3 Floorboard required to achieve the various U–values to satisfy
Building Regulation/Standards.
1 The
l–value quoted is based on the procedures
for the determination of the aged values of thermal resistance and
thermal conductivity, laid down by the harmonised European standard
BS EN 13166, using so called 90/90 principles. Comparison with alternative
products may not be appropriate unless the same procedures have been
followed.
2 For the purposes of these calculations
using the method as detailed in BS EN ISO 13370: 1998, the soil has
been assumed to be clay or silt, the wall insulation is assumed to
overlap the floor insulation by 200 mm minimum and the standard of
workmanship has been assumed good and therefore the correction factor
for air gaps ignored.
FIXING DETAILS
Ensure boards are laid above the damp proof membrane, and that
the d.p.m. maintains continuity with the damp proof course installed
in the surrounding walls.
The boards must be continuously supported over a level surface
free from projections. A thin sand blinding may be used to achieve
this over tamped slabs or rolled hardcore.
A 20 mm thickness of KingspanKooltherm® K3
Floorboard should
be used to insulate the perimeter of the floor. By insulating
the full depth of the screed/screed and slab, cold bridging will
be eliminated.
Lay boards with butted, staggered joints and overlay with a
polythene sheet (min 500 gauge) to act as a vapour control layer
and to prevent wet screeds penetrating the board joints.
For domestic constructions complete the floor with a 65 mm min
thickness sand/ cement screed laid over the polythene sheet (75
mm thickness in other buildings).
Alternatively the floor slab can be cast over the boards/polythene.
Ensure boards are protected during installation from wheeled/foot
traffic by using scaffold planks etc.
Boards may be cut using a sharp knife or fine toothed saw.
PRODUCT DATA
Figure 2 Below
the Floor Screed
KingspanKooltherm® K3
Floorboard
Board Size
2.4 (1.2) x 1.2 (0.6)
Insulant Thickness(mm)
Refer to local distributor or Kingspan Insulation price list
for current stock and non-stock sizes.