INTRODUCTION
For insulating directly over timber joists we recommend the use of
KingspanThermaroof TR31 zero ODP. Incorporating
a 6 mm WBP plywood upper surface and a foil underside, KingspanThermaroof TR31 zero ODP combines decking, insulation
and vapour control layer in a single product. Suitable for use beneath
built–up felt roofing systems this offers all the benefits of a warm
roof construction whilst being quick and simple to install. Ideal
for both newbuild and refurbishment.
Figure 1
PRODUCT DATA
ACHIEVING U–VALUES
1 Thickness does not include 6 mm WBP Plywood.
2 With appropriate waterproofing and chippings.
3 Based on 3 layers of partially bonded built
up felt with the surface covered in mineral chippings, a Kingspan
Thermaroof TR31 zero ODP board is laid over the timber joists with
a skim coated single layer of 12.5 mm plasterboard fixed to the underside.
For the purpose of these calculations the standard of workmanship
has been assumed good and therefore the correction factor for air
gaps has been ignored.
4 Product thickness = insulant thickness + 6
mm ply.
5 Due to limited lengths of fixings, 96 mm overall
depth of Kingspan Thermaroof TR31 zero ODP is the maximum practical
thickness. In order to achieve 0.22 W/m².K 20 mm Kingspan Thermapitch
TP10 zero ODP is required between rafters. (See page 12 for details
of Kingspan Thermapitch TP10 zero ODP.)
6 The l–value quoted
is in accordance with the Harmonised European Standard BS EN 13165
(urethane) and BS EN 13166 (phenolic) using so called 90/90 principles.
Comparison with alternative products may not be appropriate unless
the same procedures have been followed.
FIXING DETAILS
Suitable for use over joists at 400 mm and 600 mm centres.
Lay boards, plywood facing upwards with long edges following joists
and with board joints staggered see figure 2.
Insulant thickness 45–50 mm
Kingspan Thermaroof TR31 zero ODP should be fixed with suitable
galvanised ring shank nails.
These are to be placed at 100 mm centres around the board edges
and at 300 mm centres along any intermediate supporting timbers.
Insulant thickness over 50 mm
Kingspan Thermaroof TR31 zero ODP should be fixed with low profile
oval head screw fixings. These are to be placed at 200 mm centres
around the board edges and at 300 mm centres along any intermediate
supporting timbers. Refer: Fixfast 01306 880299 SFS Intec Limited
01132 085500
General
All edges of the board should be supported. The use of 50 x
50 mm cross–noggins will ensure this along the boards shorter
edges and where boards may be cut at openings or details.
A wide bead of non–setting gun–grade mastic sealant, applied
along the centre of the joists and cross–noggins will ensure a
continuous vapour control layer on the foil underside of the boards.
The mastic sealant must be wide enough to accommodate two board
edges butted together see figure 3.
Refer: Adshead Ratcliffe & Co Ltd 01773 826661, C M Sealants 0208
519 6358.
Sheets should be lightly butted (approx. 2 mm gap) whilst maintaining
a 20 mm bearing at edges over supporting timbers.
Fixings should not be positioned within 10 mm of the board edges
or within 50 mm of the corners.
Care should be taken to keep the decking dry prior to waterproofing.
Always utilise a type 3G felt as the base layer to a 3 layer felt
system.
To avoid cold bridging ensure the wall insulation around the
roof perimeter is carried up 300 mm (min) above to the underside
of the insulated deck.
This creates a warm roof construction, therefore ventilation
is not necessary.
Cutting should be carried out using a fine toothed saw.